369 research outputs found

    Precision absolute positional measurement of laser beams

    Get PDF
    We describe an instrument which, coupled with a suitable coordinate measuring machine, facilitates the absolute measurement within the machine frame of the propagation direction of a millimeter-scale laser beam to an accuracy of around ±4  Όm in position and ±20  Όrad in angle

    Wavelets and graph C∗C^*-algebras

    Full text link
    Here we give an overview on the connection between wavelet theory and representation theory for graph C∗C^{\ast}-algebras, including the higher-rank graph C∗C^*-algebras of A. Kumjian and D. Pask. Many authors have studied different aspects of this connection over the last 20 years, and we begin this paper with a survey of the known results. We then discuss several new ways to generalize these results and obtain wavelets associated to representations of higher-rank graphs. In \cite{FGKP}, we introduced the "cubical wavelets" associated to a higher-rank graph. Here, we generalize this construction to build wavelets of arbitrary shapes. We also present a different but related construction of wavelets associated to a higher-rank graph, which we anticipate will have applications to traffic analysis on networks. Finally, we generalize the spectral graph wavelets of \cite{hammond} to higher-rank graphs, giving a third family of wavelets associated to higher-rank graphs

    Results of the First Coincident Observations by Two Laser-Interferometric Gravitational Wave Detectors

    Get PDF
    We report an upper bound on the strain amplitude of gravitational wave bursts in a waveband from around 800Hz to 1.25kHz. In an effective coincident observing period of 62 hours, the prototype laser interferometric gravitational wave detectors of the University of Glasgow and Max Planck Institute for Quantum Optics, have set a limit of 4.9E-16, averaging over wave polarizations and incident directions. This is roughly a factor of 2 worse than the theoretical best limit that the detectors could have set, the excess being due to unmodelled non-Gaussian noise. The experiment has demonstrated the viability of the kind of observations planned for the large-scale interferometers that should be on-line in a few years time.Comment: 11 pages, 2 postscript figure

    Solubility, Light Output and Energy Resolution Studies of Molybdenum-Loaded Liquid Scintillators

    Get PDF
    The search for neutrinoless double-beta decay is an important part of the global neutrino physics program. One double-beta decay isotope currently under investigation is 100Mo. In this article, we discuss the results of a feasibility study investigating the use of molybdenum-loaded liquid scintillator. A large, molybdenum-loaded liquid scintillator detector is one potential design for a low-background, internal-source neutrinoless double-beta decay search with 100Mo. The program outlined in this article included the selection of a solute containing molybdenum, a scintillating solvent and the evaluation of the mixture's performance as a radiation detector.Comment: 8 pages, 3 figure

    An Automated System for Hydroxide Catalysis Bonding of Precision-Aligned Optical Systems

    Get PDF
    Precision-aligned, robust, ultra-stable optical assemblies are required in an increasing number of space-based applications such as fundamental science, metrology and geodesy. Hydroxide catalysis bonding is a proven, glue-free, technology for building such optical systems from materials such as ULE, Zerodur and fused silica. Hydroxide catalysis bonded optical systems have flown in missions such as GP-B and LISA Pathfinder achieving picometer path-length stability and microradian component stability over full mission lifetime. Component alignment and bonding was previously a largely manual process that required skilled operators and significant time. We have recently automated most of the alignment and bonding steps with the goals of improving overall precision, speed and reliability. Positioning and bonding of an optical component to within 4 microns and 10 microradians of a target position and alignment can now be reliably completed within half an hour, compared to the many hours typically taken previously. The key new features of this system are an interferometer that monitors the parallelism and separation of the surfaces to be bonded and a precision multi-axis manipulator that can optimise component alignment as it brings it down to the point of bonding. We present a description of the system and a summary of the alignment results obtained in a series of 9 test bonds. We also show how this system is being developed for integration into a precision optical manufacturing facility for assembly of large optical systems

    SARS-CoV-2 positivity in asymptomatic-screened dental patients

    Get PDF
    Enhanced community surveillance is a key pillar of the public health response to COVID-19. Asymptomatic carriage of SARS-CoV-2 is a potentially significant source of transmission, yet remains relatively poorly understood. Disruption of dental services continues with significantly reduced capacity. Ongoing precautions include pre- and/or at appointment COVID-19 symptom screening and use of enhanced personal protective equipment (PPE). This study aimed to investigate SARS-CoV-2 infection in dental patients to inform community surveillance and improve understanding of risks in the dental setting. Thirty-one dental care centres across Scotland invited asymptomatic screened patients over 5-years-old to participate. Following verbal consent and completion of sociodemographic and symptom history questionnaire, trained dental teams took a combined oropharyngeal and nasal swab sample using standardised VTM-containing testkits. Samples were processed by the Lighthouse Lab and patients informed of their results by SMS/e-mail with appropriate self-isolation guidance in the event of a positive test. All positive cases were successfully followed up by the national contact tracing program. Over a 13-week period (from 3August to 31October2020) n=4,032 patients, largely representative of the population, were tested. Of these n=22 (0.5%; 95%CI 0.5%, 0.8%) tested positive for SARS-CoV-2. The positivity rate increased over the period, commensurate with uptick in community prevalence identified across all national testing monitoring data streams. To the best of our knowledge this is the first report of a COVID-19 testing survey in asymptomatic-screened patients presenting in a dental setting. The positivity rate in this patient group reflects the underlying prevalence in community at the time. These data are a salient reminder, particularly when community infection levels are rising, of the importance of appropriate ongoing Infection Prevention Control and PPE vigilance, which is relevant as healthcare team fatigue increases as the pandemic continues. Dental settings are a valuable location for public health surveillance

    Design and construction of a telescope simulator for LISA optical bench testing

    Get PDF
    LISA (Laser Interferometer Space Antenna) is a proposed space-based instrument for astrophysical observations via the measurement of gravitational waves at mHz frequencies. The triangular constellation of the three LISA satellites will allow interferometric measurement of the changes in distance along the arms. On board each LISA satellite there will be two optical benches, one for each testmass, that measure the distance to the local test mass and to the remote optical bench on the distant satellite. For technology development, an Optical Bench Elegant Bread Board (OB EBB) is currently under construction. To verify the performance of the EBB, another optical bench - the so-called telescope simulator bench - will be constructed to simulate the beam coming from the far spacecraft. The optical beam from the telescope simulator will be superimposed with the light on the LISA OB, in order to simulate the link between two LISA satellites. Similarly in reverse, the optical beam from the LISA OB will be picked up and measured on the telescope simulator bench. Furthermore, the telescope simulator houses a test mass simulator. A gold coated mirror which can be manipulated by an actuator simulates the test mass movements. This paper presents the layout and design of the bench for the telescope simulator and test mass simulator

    On the Detection of a Scalar Stochastic Background of Gravitational Waves

    Get PDF
    In the near future we will witness the coming to a full operational regime of laser interferometers and resonant mass detectors of spherical shape. In this work we study the sensitivity of pairs of such gravitational wave detectors to a scalar stochastic background of gravitational waves. Our computations are carried out both for minimal and non minimal coupling of the scalar fields.Comment: 25 pages, 3 figure

    Optical suppression of tilt-to-length coupling in the LISA long-arm interferometer

    Get PDF
    The arm length and the isolation in space enable the Laser Interferometer Space Antenna (LISA) to probe for signals unattainable on the ground, opening a window to the subhertz gravitational-wave universe. The coupling of unavoidable angular spacecraft jitter into the longitudinal displacement measurement, an effect known as tilt-to-length (TTL) coupling, is critical for realizing the required sensitivity of picometer / √ Hz . An ultrastable interferometer test bed has been developed in order to investigate this issue and validate mitigation strategies in a setup representative of LISA and in this paper it is operated in the long-arm interferometer configuration. The test bed is fitted with a flat-top beam generator to simulate the beam received by a LISA spacecraft. We demonstrate a reduction of TTL coupling between this flat-top beam and a Gaussian reference beam via the introduction of two- and four-lens imaging systems. TTL coupling factors below ± 25 ÎŒ m / rad for beam tilts within ± 300 ÎŒ rad are obtained by careful optimization of the system. Moreover, we show that the additional TTL coupling due to lateral-alignment errors of elements of the imaging system can be compensated by introducing lateral shifts of the detector and vice versa. These findings help validate the suitability of this noise-reduction technique for the LISA long-arm interferometer

    Optical bench development for LISA

    Get PDF
    For observation of gravitational waves at frequencies between 30 ÎŒHz and 1 Hz, the LISA mission will be implemented in a triangular constellation of three identical spacecraft, which are mutually linked by laser interferometry in an active transponder scheme over a 5 million kilometer arm length. On the end point of each laser link, remote and local beam metrology with respect to inertial proof masses inside the spacecraft is realized by the LISA Optical Bench. It implements further- more various ancillary functions such as point-ahead correction, acquisition sensing, transmit beam conditioning, and laser redundancy switching. A comprehensive design of the Optical Bench has been developed, which includes all of the above mentioned functions and at the same time ensures manufacturability on the basis of hydroxide catalysis bonding, an ultrastable integration technology already perfected in the context of LISA's technology demonstrator mission LISA Pathfinder. Essential elements of this design have been validated by dedicated pre-investigations. These include the demonstration of polarizing heterodyne interferometry at the required Picometer and Nanoradian performance levels, the investigation of potential non-reciprocal noise sources in the so-called backlink fiber, as well as the development of a laser redundancy switch breadboard
    • 

    corecore